Part Number: ETI0001-1235
NSN: 6130-01-456-5656
US Navy / NSWC Rugged Mil Spec® 1000 VA UPS and
28 VDC Power Source with
Dual Source Input and Cold Start
Naval Surface Warfare Center Control
System
Rugged Mil Spec Rack or Fixed Mount 1.0 kVA AC and DC UPS
W/Dual Source Input and External Battery Module
P/N: ETI0001-1235 Rugged Mil Spec UPS Standard Front Panel Layout
NSN: 6130-01-456-5656
P/N: ETI0001-1235 Rugged Mil Spec UPS Standard Rear Panel Layout
The field proven Rugged Power UPS line is ideally suited for military,
industrial, computer and telecommunications applications requiring high reliability, rugged
construction, compact size and light weight design. These units are equally
suited for use in shipboard, airborne, vehicular, field deployed or fixed
locations with controlled or uncontrolled environments.
The “ETI0001-1235” is being used by Naval Surface Warfare Center as the
power source for critical ship controls because of the stringent performance
and reliability requirements.
The heavy-duty chassis, occupying only 5.25”
(3U) by 23.5” depth, has rounded metal corners and rugged handles front
and rear, aiding in safe handling. Internally, all major components are well
secured and electrically insulated to prevent damage due to shock and
vibration.
The internal shielded
input transformer provides galvanic isolation with provisions for domestic (115
VAC, CONUS) and optionally for international (230 VAC, OCONUS) input
voltages. For
field deployed scenarios, the Cold Start feature allows the unit to run from its
battery module before external AC is available. Special EMI/RFI filters
and input power factor correction minimize both input current and harmonics. The
input switch and the galvanic isolation transformer
all provide a double pole isolated source for all installations including shipboard systems or
overseas locations where phase references and grounding are not consistent. To
provide added flexibility and reliability, the “ETI0001-1235” accepts two independent
AC power sources and includes inrush current limiting. The UPS can operate from
either power source automatically and does not use its battery unless both
sources have failed.
The
unit also operates as a frequency converter, taking 46-70 hertz input and
converting it to clean, uninterruptible 60 hertz power. The “ETI0001-1235” has the
added benefit of having an internally redundant 28 VDC DC power source output.
The LED arrays keep the operator
informed as to the unit's status including load and battery levels. The
high intensity audible alarm can be heard in high noise environments. All
controls and protective devices are brought to the front and rear panels with critical
switches having finger guards. Further, all front panel devices are recessed to
prevent damage or accidental operation. The
input switch and the galvanic isolation transformer
all provide a double pole isolated source for all installations including shipboard systems or
overseas locations where phase references and grounding are not consistent.
The rear panel provides locking connectors for the input
and output power. Removable and washable air filters and a high capacity
stainless steel ball
bearing fan provide added protection in both controlled and hostile
environments. The exhaust air is diverted out the front vents, with
alternate air flow directions optional. The batteries are maintenance free with immobilized electrolyte and are
constructed of flame retardant materials. For more information, see the
Battery
Technology section. The
Status connector provides an interface with optional computer software
providing loss of AC and low battery status as well as remote shut down
capability.
See the Power Distribution Units section for a
listing of stand alone PDUs. See the N5 Series section for
versions of UPS with an integrated PDU and remote control.
Overall, the Rugged Power line is uniquely qualified for critical
shipboard, vehicle, airborne or land based systems combining advanced modular design
features with highly reliable construction.
Technical Specifications:
P/N: ETI0001-1235
NSN: 6130-01-456-5656
AC OUTPUT |
Output voltage: |
120 VAC true sinewave std, up to
600 VAC
optional |
Output rating: UPS |
1000 VA 0.65-0.75 pf standard
including DC output |
Non-linear load capacity: |
Up to 100% non-linear load capability w/o
derating |
Output voltage regulation: UPS |
± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step) |
Overload surge capacity: |
110% for 10 minutes; 125% for 30 seconds |
Harmonic distortion: |
Less than 5.0% into 100% non-linear load |
Output frequency: UPS |
60 Hz ± 1.0% independent of input frequency
50, 400 or 1000 Hz
output available as an option |
Operational status |
Status, load and battery LEDs, w/contacts
+90 dB audible alarm, alarm on/off inhibited |
DC OUTPUT |
Output voltage / rating: DC |
28 VDC / 300 watt |
Output voltage regulation: |
± 2.0% static regulation of nominal |
Overload surge capacity: |
110% continuously |
Output protection: |
Front panel mounted fuse (DC) |
AC INPUT |
Input voltage selection: |
Dual Source Input, two separate AC sources,
J1A and J1B
Nominal 120 VAC, optional
autoranging input of 85-270 VAC |
Input voltage tolerance: UPS |
85-135 VAC @ full load without
using battery, to 70 VAC @ 75% load |
Input frequency: |
From 46 Hz to 70 Hz standard,
optional to 440 Hz |
Input power factor: |
Better than 99% typically |
Input/output isolation: |
1000 VA, up to 120 dB common mode, <1.0
mA
leakage |
Input transient suppression: |
Complies with IEEE 587 and UL 1449 |
Input control/protection: |
Guarded 2 pole switch (S1) w/fuse (F2A and
F2B)
Cold start to turn on w/o AC present |
Input power connections: |
Two MS 3102A-22-2P, 3 pin, locking |
EXTERNAL BATTERY |
External
battery type: |
Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+) |
External battery life: |
Rated for continuous service life of 5 years |
External DC protection: |
Front panel mounted fuse (F1) |
DISTRIBUTION PANEL |
Output circuits: |
One AC and one DC outputs
standard |
Output control: |
Optional remote control panel w/rocker
switches |
Output receptacles: AC output
DC output |
MS3102A22-2S,
3 pin locking standard, various options
MS3470W14-5S, 5 pin locking
standard |
MECHANICAL |
Dimensions (H x D x W): |
5.25 (3U) x 23.5 x 19.0 in (133
x 597 x 483 mm) |
Rack Slide Mount Patterns: |
Jonathan, General Devices
patterns, others optional |
Alternate Mounting Options: |
Table, Wall, Floor, Portable,
Horizontal/Vertical |
Unit weight: |
88 lb. (40 kg) with lift handles
front and rear |
Audible noise: |
Less than 47 dB @ 5.0 ft., ANSI "A"
scale |
Cooling type: |
High capacity, positive pressure, forced air |
Cooling air direction: |
Rear intake, exhaust to front,
others optional |
Air intake filter: |
Washable metal filter media, others optional |
ENVIRONMENTAL |
Storage temperature: |
-40° to 158° F ambient (-40° to 70° C) with fully charged batteries |
Operating temperature: |
-4° to 131° F ambient ( -20° to 55° C), lower/ higher optional |
Operating humidity: |
0 to 95% relative humidity (non-condensing) |
Storage elevation: |
Up to 40,000 ft (12,192 m) |
Operating elevation: |
Up to 15,000 ft (4,572 m), higher optional |
STANDARDS |
United States: |
Meets UL-1778 standard for UPS equipment,
MIL STDs 167-1, 454, 810, 901D Grade A, 1399-300A & 2000 |
Canada: |
CSA C22.2 No. 107 UPS safety requirements |
EMI Protection: |
EMI/RFI FCC Part 15, Class A;
EN55022; MIL
STD 461 |
OPTIONAL ACCESSORIES |
|
Autoranging International Input,
Emergency Power Off, Elapsed Time Meter, Alternate I/O Configurations, Battery Expansion, Batteryless Operation, Battery
Charger/Conditioner, Power Distribution Units, Software
Interface, Asynchronous serial COM port, 10BaseT
Ethernet SNMP/HTTP port, Transport Cases,
Slides and Mounting Kits |