The Standard in Rugged Power Products

Home Up Products Representation Employment News Resources Search Feedback

ETI0003-1039 20 Amp All of these products are manufactured by ETI in the United States.

Up
ETI0003-1001 20 Amp
ETI0003-1013 60 Amp
ETI0003-1021 20 Amp
ETI0003-1031 30 Amp
ETI0003-1039 20 Amp
ETI0003-1041 20 Amp
ETI0003-1066 60 Amp
ETI0003-1070 60 Amp
ETI0003-1171 20 Amp
ETI0003-1175 30 Amp

Part Number: ETI0003-1039
Model: ETI0003-FA1/20/120
Rugged Rackmount Power Distribution Unit
with UPS Interface and Remote Control

Navy IT-21, BGPHES, SPAWAR Standard Product
Rugged PowerÔ ETI0003-FA1 Configuration with UPS Interface
20 Amp Rugged Rack Mount PDU w/ 6 Circuit, 2 Pole,
Intelligent, Solidstate Controls and Remote Control Panel
Safety, Thermal and UPS Interlocks

ETI0003-FA1 PDU Front View
ETI0003-FA1/20/120 Standard Front Panel Layout (w/ Remote Control Panel off)

ETI0003-FA1 PDU Rear View
ETI0003-FA1/20/120 Standard Rear Panel Layout

The field proven Rugged Systems™ Power Distribution Unit (PDU) line is ideally suited for military, industrial and telecommunications applications requiring a rugged rack, vehicular or field deployable, high reliability, compact size and light weight design. The heavy-duty chassis occupies only 2U (3.5”) of rack space while controlling up to 2400 VA of power via six double pole controls. The rounded metal corners and rugged handles aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. All controls and protective devices are brought to the front panel with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The control panel contains individual control breakers, alarm silence switch and alarm LEDs.

The LED arrays keep the operator informed as to the unit's status. An alarm will flash its respective LED until acknowledged. Once the alarm reset is pressed, the LED will remain on steady until the alarm is cleared. The intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battleshort override. Each load can have an external interlock to turn off power to equipment when it is not fully engaged in the rack or becomes overheated. The rack may be equipped with both a thermal warning and a thermal shutdown sensor that the PDU uses to alarm and shut down all the loads to avoid damage or thermal runaway. A Battleshort signal will override both the thermal and interlock signals. An external Fan Fail or auxiliary alarm signal can also brought in to annunciate. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. The double pole input breaker provides overload and short circuit protection for the connected UPS input isolation transformer and rack fans. The PDU circuit breaker on/off operation is also interlocked to control the UPS on/off function as well. Power from the UPS is brought back to the PDU to be distributed to the loads. Each load is controlled by a double pole solidstate relay avoiding accidental operation due to shock or vibration. The elapsed time hour meter tracks the rack equipment operation for maintenance. 

The rear panel provides locking connectors for the input power, output power, alarm and control signals. Appropriate jumper plugs are available for options not used in a particular rack system.

Overall, the Rugged Power product line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

Technical Specifications

AC INPUT FROM RACK
PDU input from rack: 120 VAC nominal, optional up to 600 VAC
INPUT MAIN (J11) connection: MS3474W18-8P, 8 pins, locking
Input protection: Guarded 2 pole, 20 amp circuit breaker
Input control: Guarded 3 pole, 20 amp toggle switch
Input power indicator: Green neon lamp
AC OUTPUT TO UPS
PDU output to UPS: Same as input from rack
AC TO UPS (J11) connection: Uses same connector as input from rack
AC INPUT FROM UPS
PDU input from UPS: 120 VAC, 60 Hz nominal, standard UPS
AC FROM UPS (J10) connection: MS3474W14-4P, 4 pins, locking
AC OUTPUT TO FANS
PDU output to fans: Same as input from rack
AC TO FANS (J12) connection: MS3474W16-8S, 8 sockets, locking
POWER DISTRIBUTION
PDU output voltage to loads: 120 VAC, 60 Hz nominal, standard UPS
Output rating to loads: Limited to lesser of 20 amps or UPS rating
Output circuits: Six controlled outputs w/2 pole ss relays
Output protection: Guarded individual 2 pole circuit breakers
CNTRLD AC OUT 1-5 (J13) connection: MS3474W20-16S, 16 sockets, locking
CONTROLLED AC OUT 6 (J3) connection: MS3474W14-5S, 5 sockets, locking
THERMAL CONTROL
Control function: Two stage thermal warning and shutdown
THERMAL CONTROL (J6): AMP 206705-1, 9 pins, locking
INTERLOCK CONTROL
Control function: Microswitches sense each equipment position
Disconnects power to load when racked out
INTERLOCK (J8) connection: AMP 206036-1, 16 pins, locking
REMOTE CONTROL
Output control/alarm silence: Local/remote control panel w/rocker switches
Operational status: LEDs for LOW BATT, AC FAIL, WARM, HOT, CPU
Adjustable +90 dB audible alarm
REMOTE CONTROL (J9) connection: MS3474W14-18S, 18 sockets, locking
UPS INTERFACE
Control function: AC Fail & Low Battery signals, UPS on/off control
UPS (J7) connection: AMP 206043-1, 14 sockets, locking
MECHANICAL
Dimensions ( H x D x W ): 3.5 (2U) x 15.0 x 19.0 in (89x381x483mm)
Rack Slide Mount Patterns: Slides or rear support mounting brackets
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Shipping weight: 20 lb. (9.1 kg) with lift handles front
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: Convection cooling
ENVIRONMENTAL
Storage temperature: -13° to 140° F ambient (-25° to 60° C )
Operating temperature: 32° to 122° F ambient (0° to 50° C ),higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Operating elevation: Up to 15,000 ft (4,572 m), higher optionally
STANDARDS
United States: Meets UL-1778 standard,
MIL STDs 901, 167 & 1399 Shock/Vib/Electrical
Canada: CSA C22.2 No. 107 safety requirements
EMI Protection: EMI/RFI FCC, Class B, MIL STD 461 
OPTIONAL ACCESSORIES
  Dual Source Input, Emergency Power Off, EMI Insertion Loss Filters, Auxiliary DC Power Supply, MS Connectors, Transient Surge Suppression, Load Sequencing

This page was last modified on: March 18, 2012
The N5 is one of the most popular configurations for new programs!

  Request Information

The N5 is one of the most popular configurations for new programs!

Home Up Products Representation Employment News Resources Search Feedback

Send questions or comments about this web site to sales@ruggedsystems.com.
Copyright © 1991-2012 Energy Technologies, Inc. All Rights Reserved. Last modified: April 10, 2012
1st Energy™, 1st Power™, 911 Power™, AC anytime™, AC anywhere™, AC backup™, Airborne UPS™, Air Force Backup™, Air Force UPS™, Army UPS™, Backup AC™, Backup Source™, Backup The Web™, Battle Power™, Blackout Prevention™, Business Back UPS™, clean UPS™, Coast Guard Power™, Coast Guard UPS™, Controlling Power™, DC backup™, Disaster Recovery Gear™, Eco Power Source™, eDocs Port™, Energy Tech™, ETI™, Expeditionary Solar™, Extreme Power Source™, Global Power Source™, Global UPS™, Homeland Security Surveillance™, Humanitarian Power™, Hybrid Energy Storage™, Improved Power™, Industrial Backup™, Intelligent PDU™,  Intelligent UPS™, Internet Power Manager™, Lab Power™, Lab UPS™, Light UPS™, Know Power™, Marine Corps Power™, Marine UPS™, Medical Grade Power™, Military Backup™, Navy Power™, Navy UPS™, Network Power Manager™, Office UPS™, open UPS™, Personal Power Source™, Petro Chem Power™, Pipeline Power™, Portable Power Plant™, Powering The Net™, Power Protection™, Power Security™, Preventing Blackouts™, Radar Power™, Railroad Power™, Redundant Power™, Renewable Source™,  Rugged Power™, Rugged Systems™, Rugged UPS™, SCADA power™, Security Gate Power™, Shipboard Power™, Shipboard UPS™, Signal Backup™, Solar Backup™, Solar Power Source™, Soldier Power™, Tactical Computers™, Tactical Medical Office™, Tactical Office™, Tactical Solar Fly™, Tactical Trailer™, Tactical Water Plant™, Telecom Power Source™, the Warfighter™, Traffic Backup™, Traffic Signal Backup™, UPStart™, Utility Backup™, and Warfighter Power™  are trademarks of Energy Technologies, Inc.

Airborne Power®, Diplomatic Power®, Expeditionary Power®, Extreme UPS®, Hybrid Energy Technologies®, Industrial Power Source®, Military Power®,  Mil Spec®, Personal Solar®, Tactical Cables®, Tactical Cooling®, Tactical Computer Workstation®, Tactical Data Vault®, Tactical Field Office®, Tactical Fuel Cells®, Tactical Generator®, Tactical Inverter®, Tactical Micro Grid®, Tactical Power®, Tactical Power Plant®, Tactical Shelter Systems®, Tactical Solar®, Tactical Solar Shelter®, Tactical UPS®, Tactical Vehicle Power®, Tactical Wind Turbine® and Ultimate Survival Gear® are registered trademarks of Energy Technologies, Inc.

Legal Statements